 TRUMPower
D E SCR IPTION
The TMP110 series of AC/DC switching power adapters are for 110 watts of continuous output power. They are enclosed in a 94V-1 rated polyphenylene-oxide case with an IEC 320 inlet to mate with interchangeable cord for world-wide use. An on/off switch can be added at request. All models meet CISPR 11 and FCC class B emission limits, and are designed for medical applications.
110 WATT MEDICAL POWER ADAPTERS
TMP110 SERIES
(MDD)
F EATU R E S
D u a l , t r i p l e o r q u a d r u p l e o u t p u ts Optional output connectors Optional on/off sw itch Optional Power Fail Detect (PFD) signal 100% burn-in W i d e i n p u t r a n g e 8 5 t o 2 6 4 VA C Input surge current protection O v e r v o l ta g e p r o t e c t i o n Overcurrent protection
Saf et y Sta n da rd A ppr o va ls
UL 2601-1 CSA C22.2 No. 601.1
TUV EN60601-1
IN PUT S PE C IF ICAT ION S
I n p u t v o l ta g e 8 5 t o 2 6 4 VA C Input frequency 47 to 63 Hz Input current 3 . 2 0 A ( r m s ) f o r 11 5 VA C 1 . 8 0 A ( r m s ) f o r 2 3 0 VA C L e a k a g e c u r r e n t 9 0 A m a x . @ 11 5 VA C , 6 0 H z 1 5 0 A m a x . @ 2 3 0 VA C , 5 0 H z
E N V IR O N M ENTA L SP E C IF ICATI O N S
Operating temperature Storage temperature Relative humidity Derating 0C to +70C -40C to +85C 5% to 95% non-condensing Derate from 100% at +50C linearly to 50% at +70C
OUTPUT SPECIFICATIONS
Output voltage/current Total output power See rating chart 110 watts maximum
GENERAL SPECIFICATIONS
Switching frequency 20KHz to 250KHz, varies with load and line Efficiency Hold-up time Line regulation Inrush current 70% minimum on single output models with Vo 12V, 65% minimum on the others 12 msec minimum at 110VAC 0.5% maximum at full load
Ripple and noise 1% peak to peak maximum Overvoltage protection Provided on output #1 only; set at 112-132% of its nominal output voltage Overcurrent protection All outputs protected to short circuit conditions Temperature coefficient All outputs 0.04%/C maximum Transient response Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500us after a 25% step load change TTL logic high for normal operation and TTL logic low upon loss of input power. This signal appears at least 1ms prior to +5V output dropping 5% below its nominal value. This signal also provides a minimum delay of 100ms after +5V is within regulation.
15 amps @ 115VAC, or 30 amps @230VAC, at 25C cold start Withstand voltage 4000VAC from input to output 1500VAC from input to ground 500VAC from output to ground MTBF 550,000 hours minimum at full load at 25C ambient, calculated per MIL-HDBK-217F, excluding DC fan. EMC Performance (EN60601-1-2: 2001) E N 5 5 0 11 : Class B conducted, Class B radiated FCC: Class B conducted, Class B radiated VCCI: Class B conducted, Class B radiated EN61000-3-2: Harmonic distortion, Class A EN61000-3-3: Line flicker EN61000-4-2: ESD, 8KV air and 6KV contact EN61000-4-3: EN61000-4-4: EN61000-4-5: EN61000-4-6: EN61000-4-8: E N 6 1 0 0 0 - 4 - 11 : Radiated immunity, 3V/m for 80~2500MHz Fast transient/burst, 2KV Surge, 1KV diff, 2KV com. Conducted immunity, 3Vrms Magnetic field immunity, 3A/m Voltage dips, 30% reduction for 500ms, 60% reduction for 100ms and >95% reduction for 10ms
PFD signal (optional):
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 Fax: 408-988-6622 email: sales@trumpower.com Website: www.TRUMPower.com
MEDICAL GRADE
OUTPUT VOLTAGE/CURRENT RATING CHART
Output #1
Product No. TMP110-D23 TMP110-T31 TMP110-T32 TMP110-Q40 TMP110-Q41 TMP110-Q42 TMP110-Q45 TMP110-Q45-1 TMP110-Q45-2 TMP110-Q46 Notes: Vnom. Imin. Imax. Tol. +5V +5V +5V +5V +5V +5V +5V +5V +5V +5V 0.8A 10A 0.8A 10A 0.8A 10A 0.8A 10A 0.8A 10A 0.8A 10A 0.8A 10A 2.0A 10A 0.8A 10A 0.8A 10A 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% +12V +12V +15V +12V +15V +12V +12V +12V +24V +15V
TMP110 SERIES
Output #2 (1)
Vnom. Imin. Imax. Ipeak Tol 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 5A 5A 4A 5A 4A 5A 5A 5A 3A 4A 9.0A 9.0A 7.5A 9.0A 7.5A 9.0A 9.0A 9.0A 5.0A 7.5A 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% -12V -15V -12V -15V -12V -12V -12V -12V -15V
Output #3
Vnom. Imin. Imax. Tol (N/A) 0A 0A 0A 0A 0A 0A 0A 0A 0A 2A 2A 2A 2A 2A 2A 2A 2A 2A 5% 5% 5% 5% 5% 5% 5% 5% 5% -5V +24V +12V +24V +24V +12V -5V
Output #4
(N/A) (N/A) (N/A) 0A 0A 0A 0A 1.5A 0A 0A 2A 2A 2A 2A 3A 2A 2A 5% 5% 5% 5%
Output
Vnom. Imin. Imax. Tol. Power 110W 110W 110W 110W 110W 110W 110W
10% 110W 5% 5% 110W 110W
(1) Peak output current with 10% maximum duty cycle for less than 60 seconds. Total peak power must not exceed 130 watts. (2) The output #1 of model TMP110-Q45-1 needs a minimum current of 2A to support the other outputs at their maximum rated loads.
MECHANICAL SPECIFICATIONS
NOTES: 1. Dimensions shown in inch [mm] 2. Tolerance 0.02 [0.5] maximum
3. 4.
Weight: 1.40 Kgs (3.08 Lbs.) approx. Standard output connector is an 8-pin at 270 male DIN plug. For other output connector options, please consult factory. To order a model with on/off switch, add suffix "S" to the product number. e.g. TMP110-T31-S. To order a model with PFD signal, add suffix "PF" to the product number, e.g. TMP110-T31-PF.
5.
6.
PIN CHART
PIN Product No. TMP110-D23 TMP110-T31 TMP110-Q40 TMP110-Q42 TMP110-Q45-1 TMP110-Q46 TMP110-T32 TMP110-Q41 TMP110-Q45 TMP110-Q45-2
1
COMMON RETURN COMMON RETURN COMMON RETURN
2
N.C. OUTPUT #3 OUTPUT #3
3
OUTPUT #1. OUTPUT #1. OUTPUT #1.
4
N.C. N.C
5
OUTPUT #2. OUTPUT #2. OUTPUT #2..
6
COMMON RETURN COMMON RETURN COMMON RETURN
7
OUTPUT #1 OUTPUT #1 OUTPUT #1
8
N.C. or PFD N.C. or PFD N.C. or PFD.
OUTPUT #4
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 Fax: 408-988-6622 email: sales@trumpower.com Website: www.TRUMPower.com


▲Up To Search▲   

 
Price & Availability of TMP110

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X